Zoeken
  • 80 jaar ervaring
  • ISO 9001-2015 gecertificeerd
  • Innovatief
  • Snelle levering via groothandel
  • Eigen advisering

Winterwarm Heating Solutions
Industrieweg 8
7102 DZ Winterswijk

Postbus 36
7100 AA Winterswijk

T: +31 (0)543 546300
F: +31 (0)543 546310
E: info@winterwarm.nl
comm. reg. 59198516

Name company/location: Prestoplan
Town: Gloucester
Country: United Kingdom
Surface heated area: appr. 7,200 m2
Volume heated area: appr. 61,200 m2
Replacement or new building: New
Activity (what is the hall used for): House timber frame construction
Desired room temperature: 15°-18° C
Total capacity: 600 kW
Type of installed heaters: 10 x XR 60
If present, recirculation units/ceiling fans: 36 x WCU 40
Year of installation: 2006
Special features: Consultant specified any equipment to be max. 50 dBa
Remarks: 6 large roller-shutter doors meant high probability of significant temperature fluctuations, therefore each hater individually controlled.